0 programming the sm-basic drive – LEESON SM-Basic Series Sub-Micro Inverters (Obsolete) User Manual
Page 22
18
Press
Mode to enter password
Use
s and t to scroll to the
password value
13.0
PROGRAMMING THE SM-Basic DRIVE
The drive may be programmed by one of two methods: using the three buttons and 2-digit LED
display on the front of the drive, or programming the Electronic Programming Module (EPM) using
the optional EPM Programmer. This section describes programming the drive using the buttons and
display, which are shown below:
To enter the PROGRAM mode to access the parameters, press the
Mode button. This will activate
the PASSWORD prompt (if the password has not been disabled). The display will read “00” and the
upper right-hand decimal point will be blinking, as shown below:
Use the
s and t buttons to scroll to the password value (the factory default password is “25”) and
press the
Mode button. Once the correct password value is entered, the display will read "01", which
indicates that the PROGRAM mode has been accessed at the beginning of the parameter menu (01 is
the first parameter), and the upper right decimal point will turn on solid. This is shown below:
Parameter menu is accessed at the
first parameter
BUTTONS
Press
Mode
Right decimal point blinks
Display reads "00"
DISPLAY
Mode
Upper right decimal point turns on solid.