LEESON SM-Basic Series Sub-Micro Inverters (Obsolete) User Manual
Page 26

22
NOTE 1:
Factory defaults are shown for a 60 Hz base frequency. See Parameter 48 for 50 Hz base frequency.
NOTE 2:
If LINE VOLTAGE is set to LOW, maximum setting is 150%.
FACTORY
FACTORY
FACTORY
FACTORY
NO.
NO.
NO.
NO.
PARAMETER NAME
PARAMETER NAME
PARAMETER NAME
PARAMETER NAME
RANGE OF ADUSTMENT
RANGE OF ADUSTMENT
RANGE OF ADUSTMENT
RANGE OF ADUSTMENT
DEFAULT
DEFAULT
DEFAULT
DEFAULT
(NOTE 1)
14
14
14
14
CONTROL
CONTROL
CONTROL
CONTROL
TERMINAL STRIP ONLY (01),
TERMINAL STRIP
REMOTE KEYPAD ONLY (02)
ONLY (01)
17
ROTATION
FORWARD ONLY (01),
FORWARD
FORWARD AND REVERSE (02)
ONLY (01)
18
TIME RANGE SELECT
x0.1 (01), x1.0 (02), x10.0 (03)
x1.0 (02)
19
ACCELERATION TIME
0.1 - 990 SEC
20 SEC
20
DECELERATION TIME
0.1 - 990 SEC
20 SEC
21
DC BRAKE TIME
0.0 - 990 SEC
0 SEC
22
DC BRAKE VOLTAGE
0 - 30 %
0 %
23
MINIMUM FREQUENCY
0 - MAXIMUM FREQUENCY
0 Hz
24
MAXIMUM FREQUENCY
MINIMUM FREQUENCY - 99 Hz
60 Hz
25
CURRENT LIMIT
30 - 180 % (NOTE 2)
180 %
26
MOTOR OVERLOAD
30 - 100 %
100 %
27
BASE FREQUENCY
25 - 99 Hz
60 Hz
28
FIXED BOOST
0 - 30 %
1 %
29
ACCEL BOOST
0 - 20 %
0 %
30
SLIP COMPENSATION
0.0 - 5.0 %
0 %
31-37
PRESET SPEEDS
0 - MAXIMUM FREQUENCY
0 Hz
38
SKIP BANDWIDTH
0 - 10 Hz
0 Hz
42
ACCEL / DECEL #2
0.1 - 990 SEC
20 SEC
44
PASSWORD
00 - 99
25
47
CLEAR HISTORY
MAINTAIN (01), CLEAR (02)
MAINTAIN (01)
48
PROGRAM
USER SETTINGS (01), OEM SETTINGS (02),
USER
SELECTION
RESET OEM (03), RESET 60 (04),
SETTINGS (01)
RESET 50 (05), TRANSLATE (06)
50
FAULT HISTORY
(VIEW-ONLY)
(N/A)
51
SOFTWARE CODE
(VIEW-ONLY)
(N/A)
52
DC BUS VOLTAGE
(VIEW-ONLY)
(N/A)
53
MOTOR VOLTAGE
(VIEW-ONLY)
(N/A)
54
LOAD
(VIEW-ONLY)
(N/A)
55
SPEED POT INPUT
(VIEW-ONLY)
(N/A)
57
TB STRIP STATUS
(VIEW-ONLY)
(N/A)
58
KEYPAD STATUS
(VIEW-ONLY)
(N/A)