6
5.0
SM Series
™
RATINGS
SM
INPUT
OUTPUT
MODEL
FOR MOTORS
50-60 Hz)
(3 Phase)
HEAT LOSS
NUMBER
RATED
INPUT
CURRENT
POWER
CURRENT
(WATTS)
(NOTE 1)
HP
kW
PHASE
(AMPS)
(kVA)
(AMPS)
(NOTE 1)
120 Vac INPUT MODELS
120 Vac
0 - 230 Vac
174263
0.33
0.25
1
6.8
0.8
1.7
29
174264
0.50
0.37
1
9.2
1.1
2.4
33
174265
1
0.75
1
16.6
2.0
4.2
57
174266
1.5
1.1
1
24
2.9
6.0
86
208/240 Vac INPUT MODELS
208/240 Vac
0 - 208/230 Vac
174267
0.33
0.25
1
3.9/3.4
0.8
1.9/1.7
23
174268
0.50
0.37
1
5.8/5.0
1.2
2.8/2.4
31
174274
0.50
0.37
3
3.1/2.7
1.1
2.8/2.4
31
174270
1
0.75
1
10.6/9.2
2.2
4.8/4.2
47
174276
1
0.75
3
5.8/5.1
2.1
4.8/4.2
47
174271
1.5
1.1
1
13.9/12.0
2.9
6.9/6.0
68
174277
1.5
1.1
3
8.0/6.9
2.9
6.9/6.0
68
174272
2
1.5
1
18.4/16.0
3.1
8.1/7.0
71
174278
2
1.5
3
9.1/7.9
3.3
8.1/7.0
71
174273
3
2.2
1
24/21
4.1
11.0/9.6
108
174279
3
2.2
3
12.4/10.8
4.5
11.0/9.6
108
174288
5
4.0
3
19.6/17.1
7.1
17.5/15.2
173
174280
7.5
5.5
3
28 / 25
10.3
25 / 22
286
174290
10
7.5
3
34 / 32
13.1
30 / 28
379
174292
15
11
3
54 / 48
20.0
48 / 42
476
400/480 Vac INPUT MODELS
400/480 Vac
0-400/460 Vac
174281
0.50
0.37
3
1.6/1.4
1.1
1.3/1.1
31
174282
1
0.75
3
3.0/2.5
2.1
2.5/2.1
47
174283
1.5
1.1
3
4.3/3.6
3.0
3.6/3.0
58
174284
2
1.5
3
4.8/4.0
3.3
4.1/3.4
63
174286
3
2.2
3
6.4/5.4
4.5
5.8/4.8
92
174287
5
4.0
3
10.6/8.8
7.1
9.4/7.8
155
174285
7.5
5.5
3
14.2 / 12.4
10.3
12.6 / 11.0
254
174291
10
7.5
3
18.1 / 15.8
13.1
16.1 / 14.0
310
174293
15
11
3
27 / 24
20.0
24 / 21
390
NOTE 1: Values are worst-case (not typical) for 6kHz carrier frequency at full speed and full load.