INSTALLATION
Installing the Heating Cable/Mat
Determine general areas where you want to install SC/SCM cable/ mat
Applications include driveways, walkways, patios, permanent ramps, masonry steps and benches, shipping docks, under garage door seals and
more. Anywhere outdoors in residential or commercial locations where snow or icE accumulate may be considered, as long as SC/SCM is
completely embedded in concrete, sand, thick mortar bed, or asphalt.
SC/SCM cable/mat cannot be installed indoors, in industrial locations, or areas with hazardous classifications. It cannot be used for pipe freeze
protection or roof/gutter snowmelt. Do not install the SC/SCM cable/mat on or under non-masonry stairs or decks such as wooden or composite
construction.
If installing SC/SCM under brick pavers we recommend installing cables under entire area. This is because non-heated area will receive melt
water that may re-freeze under the pavers causing the pavers to heave in the non-heated area. (If you have an application you are unsure of,
please consult factory for advice.
SURFACES THAT CAN BE INSTALLED UNDER (Continued)
SAVE THESE INSTRUCTIONS
INSTALLATION INSTRUCTIONS
DANGER
!
!
ELECTRIC SHOCK OR FIRE HAZARD
READ ALL WIRE SIZING, VOLTAGE REQUIREMENTS AND SAFETY
DATA TO AVOID PROPERTY DAMAGE AND PERSONAL INJURY