Maintenance & Cleaning: Basic maintenance is listed below. All other servicing should be performed by qualified

service personnel. Your heater will give you years of service and comfort with only minimum care. To assure effi-
cient operation clean the unit via the simple instructions below. Cleaning should be preformed annually.

WARNING: Turn the electrical power OFF at the electrical panel board (circuit breaker or fuse box) and
lock or tag this panel board door to prevent someone from turning on power while you are working on

this heater. Failure to do so could result in serious electrical shock, burns, or possible death.

Remote Wall Thermostat

Warranty Information

King Electrical Manufacturing Company will repair or replace, without charge to the original owner, any KT Series

Toe Space heater found to be defective or malfunctioning within 1 year of installation. If the product becomes
defective, contact King at 206-762-0400 for instructions on how to replace heater. Do not return the heater to

the store. All returned goods require a Returned Goods Authorization. This warranty requires the owner or his
agent install the heater in accordance with these instruction, the National Electrical Code and any other applica-

ble heating or electrical codes. It further requires that reasonable and necessary maintenance be performed on
the unit. The company is not liable for abuse or misuse of product. King Electrical Manufacturing Company is not

responsible for replacement of discolored flooring material due to hot air from this heater. Suitable installation
and placement selection for this heater is the responsibility of the installer and the end user.

1. Before removing grille, turn the electrical power OFF. Circuit breakers are often not marked correctly and turn-

ing the wrong breaker off could mean electricity is flowing to the heater, even if the heater does not appear to
be working. If you are uncomfortable working with electrical appliances, unable to follow these guidelines, or do

not have the necessary equipment, consult a qualified electrician. Once you verify the power is off completely,
proceed to the next step.

2. Remove screws and take off grille. Wash grille with hot soapy water and dry immediately
3. Using a hair dryer or vacuum on blow cycle, blow debris back through the element. Do not touch element.

Vacuum lose debris without touching the elements.

The fan motor does not require lubrication.

4. Replace grille and secure with screws.

5. Turn thermostat to desired setting.
6. Turn power back ON at the electrical panel board.

Before cleaning this heater, the heating element of the heater must be cool.

Figure 2

Figure 6

Connection Diagram for Wall Mounted Single Pole Thermostat

1. Red thermostat wire to black power supply wire.

2. Black thermostat wire to black heater wire.
3. White power supply wire to white heater wire.

4. Connect all bare ground wires together.

Connection Diagram for Wall Mounted Double Pole Thermostat

1. Connect the two red thermostat wires to the black

and white power supply wires.

2. Connect the two black thermostat wires to the black

and white heater wires.

3. Connect all the bare ground wires together.

Kt_install_2012.pub