F1 sw6 blu, A+ l1 l2 a- tb1 f2, Wht sw3 – KB Electronics KBWM-240 User Manual
Page 13: Figure 7 – internal connection diagram
11
MAX
MIN
P2
P3
P1
I1
I2
ACCEL
DECEL
L1
T
L2
B
F+
F1
SW6
BLU
LINE
ARM
A+
L1
L2
A-
TB1
F2
IR
CL
F-
WHT
SW3
180V
90V
J2
BLUE (L2)
ON/OFF SWITCH
WHITE (L1)
WHITE (SW3)
BLUE (SW6)
ORANGE (P2)
VIOLET (P3)
WHITE (P1)
MAIN SPEED POTENTIOMETER
ENCLOSURE COVER
GROUND SCREW
ENCLOSURE BASE
LINE FUSE
(FACTORY INSTALLED)
(CUSTOMER INSTALLED)
ARMATURE FUSE
PLUG-IN
HORSEPOWER RESISTOR
(CUSTOMER INSTALLED)
ON KBWM-240 ONLY
J2 IS INSTALLED
CL LED
FIGURE 7 – INTERNAL CONNECTION DIAGRAM
This manual is related to the following products:
See also other documents in the category KB Electronics Software:
- KBVF-13 (45 pages)
- KBVF-27 (29 pages)
- KBDF-13 (73 pages)
- KBMA-24D (25 pages)
- KBWA-22D (36 pages)
- KBMK-24D (53 pages)
- KBDA-24D (57 pages)
- KBDA-29 (1P) (57 pages)
- KBDA-24P (57 pages)
- KBAC-24D (28 pages)
- KBAC-29 (1P) (29 pages)
- SIVFR (28 pages)
- DBM Dynamic Braking Module for Single Phase Input Models (4 pages)
- Power On/Off Switch Kit (2 pages)
- IODA, Input/Output Module for use with all KBDA/KBMK Controls (44 pages)
- SIAC, Signal Isolator, installs inside all KBAC Controls (6 pages)
- KBAC/KBDA -24D Power On/Off Switch Kit (1 page)
- KBAC/KBDA-27D Power On/Off Switch Kit (1 page)
- RFAC-24D CE Approved AC Line Filter, installs inside KBAC/KBDA-24D(Class A) (1 page)
- Fittings (KBAC/KBDA Liquid Tight Fittings, 3 x 0.5, 1 x 0.75")" (1 page)
- KBRF-200A CE Approved AC Line Filter for SCR Controls (Class A) (4 pages)
- KBRF-300 CE Approved AC Line Filter (Class B) (8 pages)
- KBTC-125 (1 page)
- KBIC-120 (28 pages)
- KBMM-125 (32 pages)
- KBWD-15 (9 pages)
- KBWS-12 (25 pages)
- KBCC-240D (22 pages)
- KBWT-16 (7 pages)
- KBMG-212D (36 pages)
- KBRG-212D (32 pages)
- KBRG-255 (18 pages)
- KBPC-225D (19 pages)
- KBPI-240D (24 pages)
- KBPW-240D (19 pages)
- KBRC-240D (24 pages)
- KBBC-24M (5 pages)
- Multi Speed Board (16 pages)
- Anti Plug Reversing Module (APRM-PC) w/Switch Kit (for Model 240D Only) (14 pages)
- KBSI-240D KBSI Signal Isolator (16 pages)