SECONDS

7.5

14.0

1.0

ACCEL TRIMPOT SETTING

0.1

15.0

FIG. 18 – ACCEL TRIMPOT ADJUSTMENT

TABLE 8 – ARMATURE FUSE CHART

Motor Horsepower

Approx. DC

Motor

Current Amps

Fuse Rating

(AC Amps)

90VDC

180VDC

1/8

1/4

1.3

2

1/6

1/3

1.7

2

1/4

1/2

2.5

4

1/3

3/4

3.3

5

1/2

1

5.0

8

3/4

1

7.5

12

1

2

10.0

20

VII. TRIMPOT ADJUSTMENTS.

The KBMG-212D contains trimpots that have been factory adjusted for most

applications. See specifications for factory settings. (Note: Fig. 12, p. 20, presents the

various trimpots with their location. They are shown in the approximate factory

position.) Some applications may require readjustment of trimpots in order to tailor

control to exact requirements. Readjust trimpots as follows:

25

A. Forward Acceleration

(FWD ACCEL) and

Reverse Acceleration

(REV ACCEL) – The FWD

ACCEL trimpot determines

the amount of time it takes

the control voltage to reach

full output in the forward

direction. It also determines

the amount of time it takes

for the control voltage, in the

reverse direction, to reach

zero output. (FWD ACCEL

is the Reverse Decel.)
The REV ACCEL trimpot

determines the amount of

time it takes the control

voltage to reach full output in the reverse direction and the time it takes for the

control voltage, in the forward direction, to reach zero output. (REV ACCEL is the

Forward Decel.)
The FWD and REV ACCEL trimpots are factory adjusted to approximately 1

second. The acceleration times are adjustable over a range of 0.1 to 15 seconds.

See fig. 18 for graphical representation of ACCEL.
Note: The FWD and REV CL trimpots may override the rapid accel and decel

settings.

26

time

SPEED

100

0

-100

(%)