beautypg.com

KB Electronics KBPC-240D User Manual

Page 19

background image

16

C. Signal Isolator (Model KBSI-240D, P/N 9431) – Signal isolation is required when a

remote nonisolated analog signal is to be used. Provision is made to install Model KBSI-

240D on 4 bosses inside the front cover. The unit accepts a variety of voltage and current

signals.

Note: Foward-Brake-Reverse Switch (P/N 9339) cannot be installed with Signal

Isolator.

D. Auto/Manual Installation Kit (P/N 9377) – This kit facilitates mounting of KBSI-240D

Signal Isolator into KBPC-240D. Contains Auto/Man Switch and necessary wiring and

hardware. (KBSI-240D, P/N 9431 purchased seperately).

E. ON/OFF AC Line Switch (P/N 9341) – This option is desirable if a positive AC Line

disconnect is required. The switch can be installed in lieu of the Start/Stop Switch (which

can be easily removed) or in place of the Run-Stop-Jog or the Forward-Brake Reverse

Switch. Installation is made via quick-connect terminals.

F. RFI Filter (Model KBRF-200A, P/N 9945A) – The KBRF-200A meets the requirements

of CE directives pertaining to RFI filtering.

G. Electronic Forward-Brake-Reverse (APRM-PC P/N 9378) – The APRM-PC provides

electronic reversing with solid state dynamic braking. Plug reversing is eliminated with

KB’s patented APRM

®

. The Unit is supplied with a FWD-BRK-REV toggle switch;

however, it can also be switched with an external switch or relay.

This manual is related to the following products: