OPTIONAL ACCESSORIES (CONTINUED)
•
DIN Rail Mounting Kit (Part No. 9995).
•
KBAP-240D Current Sensing Overload Protector (Part No. 9106): Provides overload current sensing
and protection of DC motors and speed controls rated 1/8 - 3 HP by sensing armature current. Operates on
115 or 208/230 Volt AC line input.
•
KBEP-240D Electronic Potentiometer (Part No. 9108): Provides digital type control of motor speed.
Replaces a standard rotary potentiometer with a set of customer supplied momentary push buttons or
membrane switches.
•
KBET-240D Electronic Tachometer (Part No. 9469): Provides an isolated tach-feedback signal and an
isolated voltage follower signal from an open collector (Hall, magnetic, inductive, and optical) or 2-wire
inductive pickup (encoder). Operates on 115 or 208/230 Volt AC line input.
•
RFI Filters: Provide RFI and EMI suppression. Rated for 208/230 Volt 50/60 Hz AC. Complies with CE
Council Directive 89/336/EEC relating to the Class A Industrial Standard and Class B Residential Standard.
Filters are available in remote or undermount types. See Table 7.
TABLE 7. RFI FILTER SELECTION
Model No.
Part No.
Current Rating
(RMS Amps)
Mounting
CE Class
KBRF-200A
9945C
24
Remote
A - Industrial
KBRF-250
9509
10
Undermount
A - Industrial
KBRF-300
9484
16
Remote
B – Residential *
KBRF-350
9511
10
Undermount
B – Residential *
* Also meets industrial standard.