Configuration Parameters
Issue 1.0 June 2002
39
DUStore
(dustore)
Enables the use of the DUStore Server. Check the check box to enable or uncheck to 
disable.
DUStore ADU Batch Size
(maxkills)
The maximum number of ADUs that are sent to the DUStore Server in one set. The 
minimum is 1 and the default is 60.
Poll Wait
(pollwait)
Sets the interval for the Toolkit's Select() method, in hundredths of a second.
The default value is 5 (50 milliseconds). Low values increase CPU utilization. High 
values (over 100) may affect the accuracy of the scaninterval parameter.
Maximum number of 
Revisions
(maxkeptrevisions)
Determines the number of revisions of a value that are kept for access with the 
GetValuesHistory() method. The default is 4, which is generally recommended.
Number of Cached Adu 
events
(keepevents)
Determines the maximum number of events to be kept in memory for each ADU. The 
default is 256. A setting of 64 is recommended as a reasonable number of events to 
be kept in memory. High values may increase Eventsink throughput. Low values may 
conserve memory.
Retry Interval
(serverretryinterval)
Specifies the number of seconds to wait between automatic attempts to reassign to 
servers. The minimum is 6 seconds, maximum is 48 hours, default is 1 minute. 
Setting this value below 30 seconds in a production environment is not 
recommended, as it does a synchronous DS call for a list of ADU Servers and 
attempts an asynchronous Assign to any of them it isn't already assigned to. If the 
Assign fails (the request function itself fails), the offending ADU Server is removed 
from the list and not retried automatically. The retry is only attempted if the Assign 
callback reveals an error or a ServerFailed event arrives.
Reset Interval
(serverresetinterval)
Specifies the number of seconds to wait between attempts to reassign to servers 
after receiving an ADU.FailADUCon alarm. The minimum is 0, maximum is 48 hours, 
default is 2 seconds.
Data Element Names
Suspend Interval
(suspendinterval)
Number of seconds before an ADU, which is suspended by use of the Suspend 
method by all users, is considered for Suspension. This parameter can be overridden 
by a higher value in the Suspend method. The minimum is 1, maximum is 20 minutes, 
default is 1 second.
Adu Data Percent
(adudata.perecnt)
The percentage of ADUs that are sent to the ADU data feed, used for random 
sampling. The minimum is 0, maximum is 100, default is 0.
Find Create to Search
(findcreatestoresearch)
Enables a WAN wide DUStore search on the FindOrCreate method. Check the check 
box to enable or uncheck to disable.
DUindex Lookup1
(duindex.lookup1)
The name of one of the fields used to index the ADU in the DUStore Server. Used 
with the Find method.
DUindex Lookup2
(duindex.lookup2)
The name of one of the fields used to index the ADU in the DUStore Server. Used 
with the Find method.
DUindex Info1
(duindex.info1)
The name of one of the fields used to identify the ADU in the DUStore Server. Used 
with the Find method.
Label