Maintenance instructions – Robinair 348012K Recovery, Recycling, Recharging Unit User Manual
Page 25
2 3
348002K/348012K Cool-Tech Recovery/Recycling/Recharging Unit
Maintenance Instructions
ELECTRICAL PROTECTION
If the circuit breaker trips, all power to the unit is lost. Press the circuit breaker
button to reset. The circuit breaker is located near the fuse on the back of the unit.
GENERAL MAINTENANCE
1. On a regular basis, wipe off the unit with a clean cloth to remove grease, dust
or other dirt.
2. Periodically check the internal components for leaks—over time, fittings can
loosen as the unit is moved. Open the unit door panel and trace lines with a
leak detector. Also, check connections on the back of the unit. Tighten any
loose fittings or connections you may find.