Operating guidelines, Using the selection menu, B. tank fill (r-134a users) – Robinair 348012K Recovery, Recycling, Recharging Unit User Manual
Page 10: Vacuum oil time
© 2000 Robinair, SPX Corporation
8
USING THE SELECTION MENU
(continued)
4-b. TANK FILL (R-134a Users)
NOTE: If using a refillable tank, place the tank upside down and connect the
lowside service hose to the vapor valve.
Set the SELECTOR switch to R-134a:
1. Connect the tank to quick-coupler adapter (supplied with the unit) to the
low side service hose.
2. Connect the low side service hose to the source tank and open valve.
3. Select TANK FILL from the Selection Menu.
4. Press
ENTER
. Then press
START
and the tank automatically refills. The
unit stops when a sufficient amount of refrigerant has been transferred to
the ESV- or - the source tank is empty.
NOTE: Press
STOP
if you wish to stop fill before it completes.
5. Close the valve on the source tank.
6. Disconnect the 96" blue service hose from the adapter, then disconnect the
adapter from the source tank.
7. Press
STOP
to exit.
VACUUM OIL TIME
This feature displays the number of hours the vacuum pump has been used since
the last oil change and needs reset after an oil change. Change the vacuum pump
oil after every 10 hours of operation. See the Maintenance section on page 20 of
this manual for instructions.
Operating Guidelines