AdaptaFlow Node Adapter - Operation
Normal Data BTR Word
Normal Data BTR Word
Normal Data BTR Word
Normal Data BTR Word
Normal Data BTR Word
Configuration
Configuration
Configuration
Configuration
Configuration
Word #
Word #
Word #
Word #
Word # Description
Description
Description
Description
Description
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Configuration Word (0)
Channel No. (1-4)
Color No. (1-32)
Actual Flow Channel No. 1 (0-999 cc/min.)
Peak Flow Channel No. 1 (0-999 cc/min.)
Total Flow Channel No. 1 (0-32768 cc)
Analog Out Channel No. 1 (0-4095)
Actual Flow Channel No. 2 (0-999 cc/min.)
Peak Flow Channel No. 2 (0-999 cc/min.)
Total Flow Channel No. 2 (0-32768 cc)
Analog Out Channel No. 2 (0-4095)
Actual Flow Channel No. 3 (0-999 cc/min.)
Peak Flow Channel No. 3 (0-999 cc/min.)
Total Flow Channel No. 3 (0-32768 cc)
Analog Out Channel No. 3 (0-4095)
Actual Flow Channel No. 4 (0-999 cc/min.)
Peak Flow Channel No. 4 (0-999 cc/min.)
Total Flow Channel No. 4 (0-32768 cc)
Analog Out Channel No. 4 (0-4095)
Figure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word Configuration
Figure 13: Normal Data BTR Word Configuration
1 9
1 9
1 9
1 9
1 9
Global Data Block T
Global Data Block T
Global Data Block T
Global Data Block T
Global Data Block Transfer
ransfer
ransfer
ransfer
ransfer
Read Operational Descriptions
Read Operational Descriptions
Read Operational Descriptions
Read Operational Descriptions
Read Operational Descriptions
-Refer to Figure 14
-Refer to Figure 14
-Refer to Figure 14
-Refer to Figure 14
-Refer to Figure 14
The Global Block Transfer Read is identified by a
configuration word of two. This file is returned
immediately following a Global BTW instruction or
this data may also be requested by setting the
Normal BTW instructions configuration word to a
two.
Configuration Word
Configuration Word
Configuration Word
Configuration Word
Configuration Word
The configuration Word will equal a 2 to designate
that this BTR file represents Global Data.
The balance of the BTR words in this file are
described under the Global BTW section.
Actual Flow
Actual Flow
Actual Flow
Actual Flow
Actual Flow
This value is the real time flow rate for each
channel.
Peak Flow
Peak Flow
Peak Flow
Peak Flow
Peak Flow
This is current peak flow for each channel.
Total Flow
Total Flow
Total Flow
Total Flow
Total Flow
Value for total accumulated fluid delivered between
totalizer reset signals. This value can be zeroed
by a software command or by a hardware reset.
This can be used as a subtotal or intermediate total
to account for fluid delivered per job or shift, etc.
Analog Out
Analog Out
Analog Out
Analog Out
Analog Out
This is the current analog output value.