Ransburg 9040 Classic Power Supply _NO2 Gun 76657-14, -142 User Manual
Page 27
CP-97-03.6
!
ALWAYS
ALWAYS
ALWAYS
ALWAYS
ALWAYS double check that the power
supply is unplugged from its AC outlet
before removing the cover plate from power
supply 1SUP.
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
W A R N I N G
!!!!!
Power Supply 1SUP
Power Supply 1SUP
Power Supply 1SUP
Power Supply 1SUP
Power Supply 1SUP
1.
Ensure power supply is unplugged from
AC outlet and open the cabinet door.
2.
Remove the (4) screws from the 1SUP
power supply cover plate and remove
the plate.
9040 Classic for the No. 2 Process Handgun - Maintenance
2 3
2 3
2 3
2 3
2 3
3.
Remove connectors 11PL and 12PL
from power supply 1SUP.
4.
Remove the (4) cover plate standoffs
from power supply 1SUP and remove
the power supply from the unit.
5.
Install new 1SUP power supply (see
"Parts Identification" section of this
manual for part numbers) using the (4)
cover plate standoffs. Ensure larger ter-
minal strip (12PL) of power supply 1SUP
faces left side of unit as shown in Figure
8.
6.
Connect connectors 11PL and 12PL to
new power supply and reinstall cover
plate.
7.
Secure cabinet door and plug power
supply back in.
24 VDC Power Supply 2SUP
24 VDC Power Supply 2SUP
24 VDC Power Supply 2SUP
24 VDC Power Supply 2SUP
24 VDC Power Supply 2SUP
1.
Remove HV cable from power supply.
2.
Ensure power supply is unplugged from
AC outlet and open cabinet door.
3.
Unplug connector 1PL from the top of
the high voltage multiplier.
4.
Remove the screws that mount the high
voltage multipliers’ aluminum housing to
the back panel.
5.
Disconnect plugs 8PL and 10PL from 24
VDC power supply 2SUP and remove
the (4) mounting screws from the relay
board.
6.
Rotate the high voltage multiplier assem-
bly out from the power supply.
7.
Remove the (4) mounting screws from
the 24 VDC supply.
8.
Install the new 24 VDC supply (see
"Parts Identification" section of this
manual for part numbers). Ensure two
pin connector of 24 VDC supply is clos-
est to bottom of unit when installing.
9.
Reinstall high voltage multiplier assem-
bly in power supply.
10.
Plug connector 1PL back into the high
voltage multiplier. Reconnect plugs 8PL
and 10PL to the 24 VDC supply and
resecure the relay board.
11.
Secure the cabinet door, plug the power
supply back in and reinstall the HV
cable.