beautypg.com

Ransburg, Shaping air / seal air test – Ransburg RMA202 Test Stand 77918-08 User Manual

Page 18

background image

8. On the atomizer speed select card, toggle the

“Enable” #1 switch down.

9. Stop the spinning bell by pressing the manual

brake button on the front panel of the test sta-

tion. Do not allow the turbine to spin in the re-

verse direction or it will damage unit.

4. Increase the shaping air pressure to 60 psig at

the gauge. Read the flow meter for airflow rate.

The rate for this pressure should be between

17 to 21 SCFM (481 SLPM to 594 SLPM).

(Note: This depends on length of shaping air

hose.)

5. Set the shaping air pressure back down to 0

psig and return the switch to the off position.

Turn off turbine.

6. Turn on “seal air” switch.

7. Increase the seal air pressure to 30 psig.

8. Select seal at flow rate select switch. Read

flow rate at the meter. The range of flow should

be between 8 SCFM to 12 SCFM (226 SLPM

to 340 SLPM).

9. Turn seal air switch off.

W A R N I N G

!

> DO NOT use your hand or any object to

stop bell cup rotation.

C A U T I O N

!

> DO NOT hold manual brake button in

below 5K rpm.

Shaping Air / Seal Air Test

1. Turn the shaping air switch to the “On” postion.

Set the shaping air pressure gage to read 25

psig by adjusting the regulator.

2. Set the atomizer speed select to 50,000 rpm.

Press the speed enter button. The turbine

should now begin spinning. This should be au-

dible.

3. Select the shaping air flow meter at the flow

rate select button. The flow rate should read

between 8 (226 SLPM) to 13 SCFM (368

SLPM) (Note: This depends on length of shap-

ing air hose.)

Figure 18: Shaping Air Controls

Figure 19: Seal Air Controls

100

100

> If the On/Off switches for the

shaping and seal air are rapidly

turned on and off, the air flow meter

may de-couple and show a zero

reading. To recouple, leave the air

On/Off switch in the on position and

adjust the regulated air pressure

back to zero.

N O T E

RMA-202 Test Stand - Installation

16

Ransburg

LN-9527-00.1