Evolver Solventborne Robotic Atomizers - Maintenance
7. The o-ring [16] should be inserted into
the front of the bushing [14] and one of the o-rings
[15] installed onto the outside groove before the
bushing is installed.
8. Reassemble the remaining parts, as shown in
Figure 9, making sure that the alignment tab on the
bushing [14] lines up with the align groove in the
body [19].
9. Torque the seal carriage [13] to 30-35 lbs•in (4.0-
4.5 Nm).
10. If the u-cup needs to be replaced, assemble
on piston plate [9] and push both onto shaft, tighten
securely with piston nut [7], and install in body as
one assembly.
11. Assemble the remainder of the gun head as
stated earlier.
12. If the locking tab plug connection [24] needs
to be replaced, first remove the electrode spring
connector [23] by pulling straight out with a needle
nose pliers. If removed, the spring wire should be
replaced.
13. Remove socket head screw [22] and connec-
tion plug [24] from body.
14. Replace conductive compressable contact [25]
if necessary.
15. Reinstall the connection plug [24] into the body,
making sure the tabs on the bottom align
with
the notches in the body [19].
16. Insert and tighten the screw [22], making sure
the tabs remain inside the notches [24] in the body.
17. Insert the spring electrode wire [23] through
the hole in the screw using a needle nose pliers
on the straight wire portion. Carefully rotate and
push the wire through the screw hole and into the
compressable contact until the spring contacts the
screw head.
>
Use Caution as NOT TO scratch or raise burrs
on inside diameters of the parts.
C A U T I O N
!
AA-03-02.11