Evolver Solventborne Robotic Atomizers - Atex
EUROPEAN ATEX DIRECTIVE 94/9/EC, ANNEX II, 1.0.6
The following instructions apply to equipment cov-
ered by certificate number Sira 05ATEX5127X:
1. The equipment may be used with flammable
gases and vapors with apparatus groups II and with
temperature class T6.
2. The equipment is only certified for use in ambi-
ent temperatures in the range +12.8
°C to +55°C and
should not be used outside this range.
3. Installation shall be carried out by suitably trained
personnel in accordance with the applicable code of
practice e.g. EN 60079-14:1997.
4. Inspection and maintenance of this equipment
shall be carried out by suitably trained personnel in
accordance with the applicable code of practice e.g.
EN 60079-17.
5. Repair of this equipment shall be carried out by
suitable trained personnel in accordance with the
applicable code of practice e.g. EN 60079-19.
6. Putting into service, use, assembling, and adjust-
ment of the equipment shall be fitted by suitably
trained personnel in accordance with the manufac-
turer's documentation.
Refer to the "Table of Contents" of this service
manual.
a. Installation
b. Operation
c. Maintenance
d. Parts Identification
7. Components to be incorporated into or used as
replacement parts of the equipment shall be fitted
by suitably trained personnel in accordance with the
manufacturer's documentation.
8. The certification of this equipment relies upon the
following materials used in its construction:
If the equipment is likely to come into contact with
aggressive substances, then it is the responsibility
of the user to take suitable precautions that prevent
it from being adversely affected, thus ensuring that
the type of protection provided by the equipment
is not compromised.
Aggressive substances: e.g. acidic liquids or
gases that may attack metals, or solvents that may
affect polymeric materials.
Suitable precautions: e.g. regular checks as part of
routine inspections or establishing from the material's
data sheets that it is resistant to specific chemicals.
Refer to "Specifications" in the "Introduction" sec-
tion:
a. All fluid passages contain stainless steel or
nylon fittings.
b. High voltage cascade is encapsulated with
a solvent resistant epoxy.
9. A recapitulation of the certification marking is de-
tailed in the "ATEX" section, on the next page, drawing
numbers: A10752, A10754, A10755, and A10915.
10. The characteristics of the equipment shall be
detailed e.g. electrical, pressure, and voltage pa-
rameters.
The manufacturer should note that, on being put
into service, the equipment must be accompanied
by a translation of the instructions in the language
or languages of the country in which the equipment
is to be used and by the instructions in the original
language.
AA-03-02.11