IS-99-01.4
4
AquaTank - Safety
AREA
Tells where hazards
may occur.
HAZARD
Tells what the hazard is.
SAFEGUARDS
Tells how to avoid the hazard.
Spray Area /
High Voltage Equip-
ment
This is a high voltage device that
can produce electrical arcs ca-
pable of igniting coating materials.
Parts being sprayed must be supported on convey-
ors or hangers and be grounded. The resistance
between the part and ground must not exceed 1
megohm. (Reference NFPA-33.)
A safe distance must be maintained between the parts
being coated and the atomizer bell. A distance of at
least 1 inch for each 10 kV of power supply output
voltage is required at all times.
Parts must be supported so that they will not swing
and reduce the clearance specified above.
All electrically conductive objects in the spray area,
with the exception of those objects required by the
process to be at high voltage, must be grounded.
Unless specifically approved for use in hazardous
locations, the power supply and other electrical
equipment must not be used in Class I, Division 1
or 2 locations.
Intended Use
Using coating materials and/or
cleaning and flushing solvents
which have flash points below
100
o
F (37.8
o
C) may cause a fire
This system is intended for use with waterborne
coating formulations only.
Waterborne, waterbase and water reducible coatings
are considered the same. Although they may not
be highly flammable, their residues are considered
combustible.