INSTALLATION

1. Follow "Pressure Relief Procedure" described

in previous "Warning".

2. To add material to the AquaTank, remove lid

and pour directly into the container.

Mix and prepare material to be used according

to manufacturer’s instructions. Strain material

through a fine mesh screen to remove lumps, skin,

and foreign matter that might enter and clog fluid

passages and/or spray equipment.

AQUATANK INSTALLATION

(Refer to Figure 3)

3. Replace the lid assembly and tighten all

securing knobs.

4. Connect ground wire to true earth ground

(reference NFPA-70).

5. The air supply hose should be connected to a

regulated air source, which should include a

filter/water separator to remove air line

impurities.

>

Pressure Relief Procedure: High pressure

can cause serious injury. Pressure is main-

tained in a pressure tank after the system

has been shut down. Before attempting

removal of fill plug or cover, pressure must

be relieved using the following steps:

• Ensure the power supply is turned OFF.

• Turn OFF the main air supply to the tank.

• BLEED OFF air in tank by pulling the air

relief valve stem, or use a relief valve at

the regulator. Wait until all the air has es-

caped through the valve before removing

the pressure tank cover or fill plug.

W A R N I N G

!

>

Static electricity is created by the flow of

fluid through the pressure tank and hose. If

all parts are not properly grounded, sparking

may occur. Sparks can ignite vapors from

solvents and the fluid being sprayed.

>

If static sparking, or slight shock is experi-

enced while using this equipment, stop spray-

ing immediately.

>

Ground the pressure tank by connect-

ing one end of a 12-gauge minimum ground

wire to the pressure tank ground stud and the

other end to a true earth ground. Local codes

may have additional grounding requirements.

W A R N I N G

!

>

Failure to ground may cause improper tank

function. The tank MUST BE grounded.

W A R N I N G

!

>

Keep fingers clear of pinch point.

NOTE

>

Use only recommended Ransburg ap-

proved fluid pail for this product. Failure to

use approved fill pail may defeat bleed

resistor function.

W A R N I N G

!