beautypg.com

Maintenance, Preventive maintenance, Bleed resistor – Ransburg AquaTank User Manual

Page 13

background image

IS-99-01.4

AquaTank - Maintenance

10

MAINTENANCE

PREVENTIVE

MAINTENANCE

1. Turn OFF air supply.

2. Turn OFF voltage at power supply/ control unit.

3. Follow "Pressure Relief Procedure" described

in previous "Warnings".

4. Remove lid by removing all hold-down knobs.

5. Remove fill pail.

6. Clean internal parts of the tank and fill pail with

appropriate solvent for the material being used.

BLEED RESISTOR

(Refer to Figure 3)

Maintenance

In the AquaTank there is a bleed resistor which

allows the charge in the tank to be connected to

ground when the power supply is not delivering

voltage to the applicator in use.

Testing

1. Ensure ALL pressure and voltage is REMOVED

from the tank.

2. Remove the tank lid assembly by removing the

star grip nuts (Item 13).

3. Remove the fill pail insert (Item 18).

4. Using a megohm meter, measure the resistance

between the ground stud on the outside of the

tank and the fill pail contact interface. This

valve should be 1 gigohm

+

/-10%. If the

resistance value is out of this range, the bleed

resistor needs to be replaced.

Replacements

For units manufactured prior to 8/99:

These units will require factory replacement of

the resistor. Ship the unit back to the factory for

replacement. After this replacement, the bleed

resistor will then be field replaceable.

For units manufactured after 8/99 or factory

serviced:

1. Loosen ground stud and remove nut and

washers.

2. Turn tank upside down to expose the bottom

of the tank.

3. Remove the 1/4-20 nuts which secure the

resistor block to the ground strap bolt (Item

23). Remove the wire from the stud.

4. Remove the 5/16-18 nuts from the outside

ground connection of the tank.

5. Pull the resistor block back to remove the bolt

from the wall of the tank. Remove the 1/4-20

bolts which secure the resistor block wire to

the tank.

> The function of the tank depends upon the

cleanliness of the INTERNAL FILL PAIL /

contact interface. This contact area MUST

be kept clean.

W A R N I N G

!

> Be careful NOT TO damage the threads

of the tank studs.

C A U T I O N

!