DR-1 Plastic Fluid Regulator - Safety

2

AREA

Tells where hazards
may occur.

HAZARD

Tells what the hazard is.

SAFEGUARDS

Tells how to avoid the hazard.

Spray Area

Fire Hazard

Improper or inadequate operation-

ing and maintenance procedures

will cause a fire hazard.

Protection against inadvertent arc-

ing that is capable of causing fire or

explosion is lost if any safety inter-

locks are disabled during operation.

Frequent power supply shutdown

indicates a problem in the system

requiring correction.

Fire extinguishing equipment must be present in the

spray area and tested periodically.

Spray areas must be kept clean to prevent the accumula-

tion of combustible residues.

Smoking must never be allowed in the spray area.

The high voltage supplied to the atomizer must be

turned off prior to cleaning, flushing or maintenance.

When using solvents for cleaning:

Those used for equipment flushing should have flash

points equal to or higher than those of the coating

material.

Those used for general cleaning must have flash points

above 100

°F (37.8°C).

Spray booth ventilation must be kept at the rates re-

quired by NFPA- 33, OSHA, and local codes. In addition,

ventilation must be maintained during cleaning opera-

tions using flammable or combustible solvents.

Electrostatic arcing must be prevented.

Test only in areas free of combustible material.

Testing may require high voltage to be on, but only as

instructed.

Non-factory replacement parts or unauthorized equip-

ment modifications may cause fire or injury.

If used, the key switch bypass is intended for use only

during set-up operations. Production should never be

done with safety interlocks disabled.

Never use equipment intended for use in waterborne

installations to spray solvent based materials.

The paint process and equipment should be set up and

operated in accordance with NFPA-33, NEC, and OSHA

requirements.