Assembly procedures – Ransburg DR-1 Plastic Fluid Regulator 75902 User Manual

Page 14

background image

DR-1 Plastic Fluid Regulator - Maintenance

11

ASSEMBLY PROCEDURES

(Refer to Figure 1)

1. Place Item 10 (o-ring) in the slot on Item 6 (lower

diaphragm retainer).

2. Place Item 8 (lower diaphragm) on the lower

diaphragm retainer with the side of the diaphragm

contacting the retainer (o-ring side).

3. Stack the following parts on the lower diaphragm,

in the following order:

• Item 7 - Center Diaphragm Retainer

• Item 16 - Bleed Spacer

• Item 14 - Center Diaphragm

• Item 5 - Upper Diaphragm Retainer

• Item 15 - Screw

4. Ensure that clearance holes in Items 8 and 14

(diaphragms) and Item 16 (bleed spacer) are aligned

properly and tighten Item 15 (screw). Use Loctite 222

on screw threads. Set this assembly aside.

5. Place lower housing on table with bottom thread-

ed opening facing "UP".

6. Insert Item 10 (o-ring) and Item 11 (regulating

seat) into the lower housing. The beveled side of the

regulating seat must be "UP".

7. Place Item 11 (regulating needle) into lower hous-

ing with the ball end against Item 11 (regulating

seat).

8. Place Item 10 (o-ring) on Item 13 (retaining

plug).

9. Place Item 12 (spring) into lower housing over Item

11 (regulating needle) and thread Item 13 (retaining

plug) into lower housing. Tighten Item 13 (retaining

plug) ensuring that needle/spring remains in the

center of the lower housing.

10. Place lower housing on table with bowl fac-

ing "UP" and place diaphragm assembly (from step

4), with pin facing "DOWN". Rotate the diaphragm

assembly so that the slot on Item 6 (lower retainer)

is 180

° to the outlet port on the lower housing for

cleaner flushing of paint.

11. Place Item 2 (spacer ring) on the top of the

diaphragm assembly with largest opening facing

"DOWN". Rotate the spacer ring, without rotating

the diaphragm assembly, so that the alignment mark

in the spacer ring is directly over the correct letter

stamped on Item 3 (lower housing). (See Figure 2 for

correct fitting alignment based on your applicator.)

12. Place Item 9 (diaphragm) on Item 2 (spacer ring)

and align holes.

13. Place Item 1 (cap) on diaphragm. Rotate the

cap, without rotating the diaphragm assembly, so

that the alignment mark is in line with the mark on

Item 2 (spacer ring) (see Figure 2).

14. Tighten opposing screws alternately to 8 lbs•in

ensuring uniform sealing of the diaphragms. Then

follow by tightening each screw in a circle pattern to

14-16 lbs•in.

>

DO NOT overtighten the air fittings. Over-

tightening the fittings may cause the stem of the

fitting to snap off.

C A U T I O N

!

>

Verify regulator seat and needle have match-

ing serial numbers.

C A U T I O N

!

>

DO NOT scratch the coating.

C A U T I O N

!

LN-9228-00.3