beautypg.com

Maintenance, Preliminary procedures, Disassembly procedures – Ransburg DR-1 Plastic Fluid Regulator 75902 User Manual

Page 12: Tools required

background image

DR-1 Plastic Fluid Regulator - Operation

9

MAINTENANCE

PRELIMINARY PROCEDURES

Prior to removing the regulator for service or repair,

perform the following:

1. If possible, flush the regulator with suitable clean-

ing solvent.

2. Turn the fluid and air "OFF" to the regulator and

disconnect the air and fluid lines from the regula-

tor.

3. Remove the regulator for service.

DISASSEMBLY PROCEDURES

(Refer to Figure 1)

TOOLS REQUIRED

• 3/4-inch Open End Wrench

• Adjustable Wrench

• Screwdriver

• Repair Kit, 73913-01

1. Remove Item 4 (8-screws) holding the regulator

assembly together with the screwdriver.

2. Remove Item 1 (cap), Item 9 (diaphragm), spacer

ring assembly and the lower housing assembly.

>

Care MUST be taken while cleaning the coated

parts of the regulator to prevent scratching.

C A U T I O N

!

>

When separating parts it may be necessary to

use a small screwdriver. Care should be taken to

NOT damage the plastic components. Damage

of these parts may cause leakage.

C A U T I O N

!

>

Unless replacing the cap or spacer ring,

it is NOT necessary to remove the air fittings.

>

The regulating needle and seat are a

matched set with matching serial numbers.

Care must be taken to not use needles and

seats with non-matching serial numbers as

fluid leakage may occur. If either compo-

nent needs to be replaced, a new matched

set must be used.

NOTE

3. With screwdriver, remove Item 15 (screw) from

the spacer ring assembly.

4. Separate Item 6 (lower diaphragm retainer), Item

10 (o-ring), Item 8 (lower diaphragm), Item 16 (bleed

spacer), Item 14 (center diaphragm) and Item 5 (upper

diaphragm retainer) from the spacer ring assembly.

5. With the 3/4-inch open-end wrench, remove

Item 13 (retaining plug), Item 12 (spring) and Item

11 (regulating needle) from Item 3 (lower housing).

6. Remove Item 11 (regulating seat) and Item 10

(o-ring) from the lower housing assembly.

7. Clean all metal parts with suitable cleaning solvent.

DO NOT use solvent on the diaphragms or o-rings.

LN-9228-00.3