Ransburg, Dip switch summary, Micropak process board dipswitch sw3-3 – Ransburg MicroPak Controller A11789 User Manual
Page 16: Micropak controller - installation
![background image](/manuals/348122/16/background.png)
DIP SWITCH SUMMARY
(See Figure 6A & 6B)
MicroPak Process Board
Dipswitch SW3-1
In remote mode, determines whether over-cur-
rent setpoint control is provided by the remote
Overcurrent Setpoint analog input or from R21 of
the MicroPak process board. If dipswitch SW3-1
is ON control is from the remote analog input. If
dipswitch SW3-1 is OFF control is from potenti-
ometer R21.
MicroPak Process Board
Dipswitch SW3-3
Determines whether high voltage is enabled
when ready mode is active. If dipswitch SW3-3 is
ON, high voltage is NOT enabled in ready mode.
Therefore, separate ready and high voltage en-
able signals are required to enable high voltage.
This is the typical setting for remote mode. If dip-
switch SW3-3 is OFF, high voltage IS enabled
when ready mode becomes active. This is the
typical setting for local (manual) mode, so that
pushing the High Voltage Enable Switch to the
ON position will enable high voltage output with-
out requiring a ready signal.
>
Dipswitch SW3-3 should never be set to
OFF while the remote Ready input is active or
high voltage will be on all of the time (when-
ever AC power is on).
W A R N I N G
!
Table 1 - Electrical I/O
Discreet I/O Board Dipswitch
SW2-1
This dipswitch is set according to the cascade in
use with the MicroPak Control Unit. It is factory
set to the ON position for use with the HP404 FM
cascade in the Evolver applicator.
Inputs:
P3 Terminal
MicroPak 1
kV Setpoint (0-10VDC)
C4
Over-current Setpoint (0-10VDC)
C3
High Voltage Reset (24VDC)
C2
High Voltage On (24VDC)
C1
Ready
A1
Outputs:
Overload (24VDC)
B4
HV Ready (24VDC)
B3
HV On (24VDC)
B2
Interlock:
Interlock Line A
A3
Other:
Ground
B1
Ground
A2
Inputs:
P3 Terminal
MicroPak 2
kV Setpoint (0-10VDC)
C8
Over-current Setpoint (0-10VDC)
C7
High Voltage Reset (24VDC)
C6
High Voltage On (24VDC)
C5
Ready
A5
Outputs:
Overload (24VDC)
B8
HV Ready (24VDC)
B7
HV On (24VDC)
B6
Interlock:
Interlock Line A
A7
Other:
Ground
B5
Ground
A6
MicroPak Controller - Installation
14
Ransburg
CP-06-01.1