Relay board, Power supply 1ps, Power supply 2ps – Ransburg 9060 HV P.S. Electric Motor 80102-21X User Manual
Page 34

9060 for No. 2 Process Handgun - Maintenance
29
CP-13-03.2
6. Secure the cabinet lid and plug the
power supply back in.
Relay Board
1. Ensure power supply is unplugged from
AC outlet and open cabinet lid.
2. Unscrew and Remove all wires from the
currently installed relay board.
3. Remove the screws that mount the relay
board to the top of the cascade.
4. Install relay board, tighten retaining screws
(4) to mount relay board on top of the
cascade.
5. Connect the ground lead from ground screw
shown in Figure 7 to the relay board termi-
nal block position 4PL-7.
6. Connect the trigger lead wire from the PC
Mainboard J3-5 connector to relay board
terminal block position 4PL-6.
7. Connect the +V (blue lead) from plug 5PL
on the power supply 2PS to the relay board
terminal block position 4PL-5.
8. Connect the orange lead from the high
voltage connector (1CON) to the relay
board terminal block position 4PL-2.
9. Connect the blue lead from the high voltage
connector (1CON) to the relay board
terminal block position 4PL-3.
10. Secure the cabinet door, replace the fuses,
and reconnect the AC source.
Power Supply 1PS
1. Ensure power supply is unplugged from
AC outlet and open cabinet lid.
2. Remove the (4) screw from the 1PS
cover plate and remove the plate.
3. Remove connectors 1PL and 2PL from
power supply 1PS.
4. Remove the (4) cover plate standoffs
from power supply 1PS and remove the
power supply from the unit.
5. Install new 1SUP power supply (See
“Parts Identification” section of this
manual for part numbers) using the (4)
cover plate standoffs. Ensure larger
terminal strip (2PL) of power supply 1PS
faces the front of unit as shown in Figure
9.
6. Connect connectors 1PL and 2PL to new
power supply and reinstall cover plate.
7. Secure cabinet door and plug power
supply back in.
Power Supply 2PS
1. Remove HV cable from power supply.
2. Ensure power supply is unplugged from
AC outlet and open cabinet lid
3. Remove the (4) screw from the 2PS
cover plate and remove the plate.
4. Remove connectors 5PL and 6PL from
power supply 2PS.
5. Remove the (4) cover plate standoffs
that mount power supply 2PS to the high
voltage multipliers’ aluminum housing.
6. Remove power supply 2PS from the unit.
7. Install the new 24 VDC supply 2PS (See
“Parts Identification” section of this
manual for part numbers). Ensure the
ALWAYS double check that the power
supply is unplugged from its AC outlet be-
fore removing the cover plate from power
supply 1SUP.
!
W A R N I N G