Service level, Replacement procedures, Fuses 1fu & 2fu – Ransburg 9060 HV P.S. Electric Motor 80102-21X User Manual
Page 32: On/off switch 1sw

9060 for No. 2 Process Handgun - Maintenance
27
CP-13-03.2
SERVICE LEVEL
Personnel who service this unit must be
qualified electronics technicians. Replace-
ment parts are designed to be made at the
assembly level. See “Parts Identification”
section of this manual for part numbers and
ordering information.
ALWAYS turn power to the power sup-
ply OFF, unplug the electrical cord from its
outlet, remove the front panel fuse, and
lock the power supply out before making
repairs or replacements.
!
W A R N I N G
DO NOT attempt to make repairs to the
printed circuit board!
DO NOT attempt to make repairs be-
yond those described. All others should
be made ONLY by Ransburg service per-
sonnel.
!
C A U T I O N
REPLACEMENT
PROCEDURES
Before making replacements, check for
defective wiring or connections between the
affected components. If there is a broken
wire, defective insulation, or dirty, loose or
corroded connections, repair or replace them
before going to the expense of replacing a
component.
Fuses 1FU & 2FU
1. Insert screwdriver into slot into the
respective fuse holder, push in, and
rotate counter-clockwise.
2. Remove screwdriver and fuse holder will
slide out.
3. Remove fuse from fuse holder and
replace with new fuse (See “Parts
Identification” section of this manual for
part numbers).
4. Insert fuse holder back into front panel
and with a slight inward pressure, rotate
screwdriver clockwise until it locks into
place.
5. Secure cabinet lib and plug power supply
back in.
ON/OFF Switch 1SW
1. Ensure power supply is unplugged from
AC outlet and open cabinet lid.
2. Remove the four quick connect terminals
from the rear of ON/OFF switch 1SW.
3. Press panel retaining clips on top and
bottom of switch 1SW together and push
switch out of panel from the inside.
4. Press new switch (See “Parts Identifica-
tion” section of this manual for part
numbers) into panel opening with termi-
nals 1A and 2A to the bottom of the
cabinet.
5. Reconnect the four quick connect
terminals to the new switch as follows:
ALWAYS double check that the power
supply is unplugged from its AC outlet be-
fore working with any internal wiring.
!
W A R N I N G
It is recommended that the four ON/
OFF switch wires be tagged with their re-
spective terminal connections to 1SW be-
fore removing.
N O T E
Two (2) spare fuses, included from the
factory, are located on the inside of the
top lid of the cabinet.
N O T E