High voltage multiplier, Main pc board – Ransburg 9060 HV P.S. Electric Motor 80102-21X User Manual
Page 33
9060 for No. 2 Process Handgun - Maintenance
CP-13-03.2
28
6. Secure cabinet door and plug power
supply back in.
High Voltage Multiplier
1. Remove HV cable from power supply.
2. Ensure power supply is unplugged from
AC outlet and open cabinet lid.
3. Unplug connector 3PL from the top of the
high voltage multiplier oscillator.
4. Unscrew (4) screws from oscillator board
and remove high voltage multiplier plug.
5. Unscrew (4) screws from relay board
mounted to top of cascade aluminum
housing.
6. Unscrew (4) screws from top play of
power supply 2PS and remove cover
plate.
7. Disconnect connection 5PL and 6PL
from power supply 2PS.
8. Unscrew (4) standoffs holding power
supply 2PS to side of cascade aluminum
housing and remove power supply.
9. Remove the screws that mount the high
voltage multipliers’ aluminum housing to
the bottom panel.
10. Remove the high voltage multiplier
assembly out from the power supply.
11. Remove the (3) screws that secure the
aluminum housing to the high voltage
multiplier.
12. Install the aluminum housing on the new
high voltage multiplier (See “Parts
Identification” section of this manual for
part numbers). Ensure connector faces
the front of the housing before installing.
13. Install the high voltage multiplier assem-
bly in the power supply by securing the
(6) mounting screws to the back panel.
14. Plug oscillator board back into cascade
plug. Screw oscillator board to cascade
with (4) screws.
15. Attach connector 3PL back into the high
voltage multiplier oscillator.
16. Mount power supply 2PS to side of the
cascade aluminum housing using the (4)
standoffs.
17. Connect 5PL and 6PL connectors back
to power supply 2PS.
18. Attach cover plate for 2PS with (4)
retaining screws.
19. Attach relay board to top of cascade
aluminum housing using the (4) retaining
screws.
20. Secure the cabinet lid and plug the
power supply back in.
21. Reinstall HV cable.
Main PC Board
1. Ensure power supply is unplugged from
AC outlet and open cabinet lid.
2. Disconnect plugs/connectors J7, J3, J2,
and J1 from main PC board. (see Figure
9).
3. Remove (3) screws from heat sink base
and lift the PC board out.
4. Insert new PC Board (See “Parts Identifi-
cation” section of this manual for part
numbers) and secure the (3) heat sink
screws.
5. Reconnect plugs J7, J3, J2, and J1.
From
To
1LF-RED or BLACK
1SW-1
1LF-BLUE
1SW-2
2TB-3
1SW-1A
2TB-4
1SW-2A