beautypg.com

Specifications, Maintenance tips – General Tools and Instruments DCS050 User Manual

Page 8

background image

SPECIFICATIONS

Field of view

60º

Minimum focal distance

(Seeker050) 4 in. (100mm)

Depth of field

(Seeker050-09) 0.5 in. to 5 in. (12.7 to 127mm)

Connection/power supply

Via USB 2.0 or 3.0 computer interface

Camera resolution

320 × 240 pixels

USB cable length

1m (3.28 ft.)

Probe length

1m (3.28 ft.)

Probe diameter

Seeker050 - 12mm (0.47 in.);
Seeker050-09 - 9mm (0.34 in.)

Operating temperature

32º to 113ºF (0º to 45ºC)

Operating relative humidity (RH) 5% to 95%, non-condensing

Storage temperature

-4º to 122ºF (-20º to 50ºC), at 85% RH or less

Dimensions

10.5 x 2.9 x 3.2 in. (266 Ч 73 Ч 80mm)

Weight of grip

12.8 oz. (363g)

MAINTENANCE TIPS

The Seeker050 requires no routine maintenance other than periodic cleaning. To clean
the instrument, use a soft dry cloth. Never use a wet cloth, solvents or water.

Although the probe and camera head are water, dust and oil-proof to IP67 standards,
refrain from immersing them in liquids or allowing them to come into contact with
corrosive chemicals. Remember that the grip is not waterproof.

Never forcibly insert or bend the probe. Nor should you bend it in more than a 2 inch
radius, or use it like a stick to clear pathways or debris.

Remember to replace the camera head’s protective rubber cap after each use of the
Seeker050. If your videos have spots, gently clean the camera head with a clean,
dry cloth.

8