beautypg.com

Vk series – General Pump VK Repair Manual User Manual

Page 5

background image

GENERAL PUMP

A member of the Interpump Group

VK SERIES

Page 5

• Perform Plug Pin - Plunger Guide disassembly.

• Proceed with disassembly of the shaft seal rings and plunger guides with common tools.

2.1.2 Reassembly of Mechanical Parts

After having checked casing cleaning, proceed with assembly of the mechanical part in the following steps:

Position the plunger guide seal rings with the relative housings on the casing as indicated in fig. 6, using

tool #F27904900.

Insert the preassembled plunger guides/con-rod unit with its upper half-bearings mounted in their

housing. Ensure that the reference notches are positioned on the correct con-rod shank

housings (1, fig. 7a). To facilitate the following tightening of the con-rod cap, it is best to position the

con-rod with the number easily visible. To facilitate shaft insertion without the tab, it is best to push

the plunger guide/con-rod unit as far down as possible, as indicated in fig. 7