8. PORTS AND CONNECTIONS

KS Series pumps are provided with (fig 4):

1 - 2 inlet ports IN Ø 2” NPT-F

Either inlet port can be used; the one not used must

be hermetically plugged.

2 - 2 outlet ports OUT Ø 1-1/2” NPT-F

3 - 3 auxiliary ports, 3/4” Gas; used for the pressure

gauge only, and for verifying correct priming.

9. PUMP INSTALLATION

9.1 Installation

The pump must be installed on a rigid and perfectly flat

and horizontal base by means of the proper four M16 x 1.5

threaded feet. The base should be rigid enough to avoid

any misalignment or flexing on the pump/transmission cou-

pling axis due to the torque involved during operation.

The unit should not be rigidly fixed on the floor

but be installed upon vibration dampeners. For

special applications contact our technical department.

An eye-bolt is provided on top of the crankcase for easy

handling of the pump. below). The eye bolt can be replaced

with a plastic cap (see below), in order to protect the thread

in the crankcase.The plastic cap is provided with the pump.

The pumps shaft (PTO) must not be rigidly connected

to the motor unit. The following transmission types are

suggested:

• Flexible joint

• Cardan joint (within the max working angles indicated

by the manufacturer).

• V-belts; allowed only for the versions without a reducer

unit.

• Hydraulic by means of a flange; for correct application,

please contact the Technical or Customer Service

Departments.

The oil plug must absolutely be replaced by the oil

stick and the oil level checked. Make sure that you can

easily reach the oil stick even after the unit has been

assembled.

9.2 Direction of rotation

An arrow situated on the crankcase near the shaft

indicates the correct direction of rotation. Standing in front

of the pump head, the direction of rotations must be:

• as shown in fig. 5 for versions with a reducer unit

• as shown in fig. 5a for versions without a reducer unit

Ref 300655 Rev D

09-12