13. PRECAUTIONS AGAINST FREEZING

Where and when there is a risk of freezing

the following precautions should be taken:

If a pump is frozen or appears frozen ON

NO ACCOUNT SHOULD THE PUMP BE

OPERATED until the entire

system has been thawed out.

14. WARRANTY TERMS

The pumps are guaranteed for a duration of 12 months

from the supply date, or 1000 working hours.

Please consult the purchase contract for other warranty

conditions. The warranty is void if:

a) The pump has been used for purposes that differ

from that agreed.

b) The pump has been fit with an electric or diesel

engine with performance greater than what is

indicated in the table.

c) The required safety devices were unadjusted or

disconnected.

d) The pump was used with accessories or spare

not supplied by General Pump or Interpump

e) Damage was caused by:

1) improper use

2) the non-observance of maintenance instructions

3) insufficient flow rate

4) use not compliant with operating instructions

5) faulty installation

6) incorrect positioning or sizing of the pipes

7) non authorized design changes

8) cavitation

12. STOPPING THE PUMP FOR LONG PERIODS

12.1 Filling the pump with an anti-corrosion emulsion

or anti-freeze solution as in the layout shown in

paragraph 9.7

a) Close the filter drain if open.

b) Be sure that the connecting pipe is clean and

spread with grease, and connect it to the high

pressure outlet port.

c) Fit a suction hose to the membrane pump. Open

the pump suction connection and fit hose between

it and the membrane pump.

d) Fill the container with the solution / emulsion.

e) Put the free extremities of the suction pipe and the

high pressure outlet pipe inside the container.

f) Start up the diaphragm pump.

g) Pump the emulsion until it comes out of the high

pressure outlet pipe.

h) Continue pumping for at least another minute; if

needed, the emulsion can re re-enforced by adding

for example Shell Donax.

i) Stop the pump, remove the pipe from the suction

connection and close it with a plug.

j) Remove the pipe from the high pressure outlet

port. Clean, grease and plug both connections and

the pipes.

12.2 Pipes

a) Before greasing and protecting the pipes according

to the previous procedure, dry the connections

using compressed air.

b) Cover with polyethylene.

c) Do not wrap them too tightly; be sure there is no

folding.

Ref 300655 Rev D