GENERAL PUMP

A member of the Interpump Group

KS SERIES

6. Do not install Venturi tubes or injectors for detergent

intake.

7. Avoid the use of standing valves, check valves, or any

other type of one-way valves.

8. Do not connect the by-pass line from the valve directly

to the pump suction line.

9. Provide appropriate baffle plates inside the tank in

order to avoid that water flows coming from both the by-

pass and feeding lines may create turbulence near the

tanks outlet port.

10. Make sure that the suction line is perfectly clean inside

before connecting it to the pump.

9.7 Filtering

On the pump suction line, install 2 filters arranged as shown

in fig 7 and fig. 7a.

The filter must be installed as close as possible to the

pump, should allow easy inspection and have the follow-

ing characteristics:

1. Minimum capacity 3 times greater than the pump’s

rated flow value.

2. Filter port diameters must not be smaller than the

pump inlet ports.

3. Filtration degree ranging between 200 and 360 µm.

In order to guarantee correct pump opera-

tion, it is important to plan periodical

cleaning of the filter depending on actual

pump usage, water quality and real

clogging conditions.

9.8 Delivery line

For a correct delivery line comply with the following

instructions:

1. The internal diameter of the pump must allow to

guarantee correct fluid speed; see diagram in

paragraph 9.9.

2. The first length of delivery hose should be flexible

in order to isolate the pump vibrations from the

rest of the system.

3. Use only high pressure hoses and fittings able to

guarantee the largest possible safety margins in

any working conditions.

4. A suitable relief valve should be installed in the

delivery line.

5. Use pressure switches suitable for the pulsating loads

typical of plunger pumps.

6. When designing the delivery line, take into proper

account the unavoidable drop in pressure, due to

its length and size.

7. If necessary, the effects of the pump pulsations

can be reduced by installing a proper pulsation

dampener in the pressure line.

9.9 Internal Diameter of the Piping

To determine the internal diameter of the piping, please

refer to the diagram on the next page.

Suction Pipe

With a flow rate of ~ 226 l/min (60 GPM) and water speed

of 1 m/sec (3.3 ft/sec). The diagram line that

connects the two scales intersects the central scale,

indicating the diameters, at a value of ~ 70 mm (2.76 in.).

Delivery Pipe

With a flow rate of ~ 226 l/min (60 GPM) and water speed

of 5.5 m/sec (18 ft./sec). The diagram line that connects

the two scales intersects the central scale,

indicating the diameters, at a value of ~ 30 mm (1.2 in.).

Optimum Speed Values

Suction: ≤ 1 m/sec (3.3 ft./sec)

Delivery: ≤ 5.5 m/sec (18 ft./sec)