Section 4: wiring, Description, Intalogix – Fairbanks MATRIX SCALE HIGHWAY SCALE SYSTEM User Manual
Page 26: Digital systems wiring, Systems installation

11/12
26
51182 Rev. 2
Section 4: Wiring
DESCRIPTION
The Matrix Scale System uses either the Intalogix
™
Digital or Analog wiring.
INTALOGIX
™
DIGITAL SYSTEMS WIRING
The Intalogix
™
Systems, which utilize Smart Sectional Controllers (SSC) and Pit
Power Supplies (PPS) for load cell excitation and signal processing.
Most applications use one (1) SSC per section, and one (1) PPS for the entire
platform.
─
This applies until the number and resistance of the cells require a second pit
power supply.
SSC boxes have four (4) terminals.
─
Two (2) terminals are used for load cells and two (2) for interfacing to other
SSC boxes or terminating to a pit power supply.
─
All cell/section/scale adjustments are made using the Intalogix
™
System
Instrument.
Intalogix
™
Systems Installation
Boxes
• The boxes are located in the Junction Box Storage Area in each PALS.
Wiring
• Cable used in all wiring must be a minimum of
18 AWG
.
• Use cable
17204
or
17246
.
• Use appropriate service manual for the indicator being installed or refer to the
Appendix I
for typical wiring information.
Smart Sectional Controller (SSC)
• Wire cells into each sections sectional controller per the appropriate service
manual. Refer to the Appendix for typical wiring information.