Section 4: user operations, Front panel key functions – Fairbanks 1155 SERIES Portable Utility SCALE WITH THE FB2255 User Manual
Page 24

02/13
24
51315 Rev. 1
Section 4: User Operations
4.1. FRONT PANEL KEY FUNCTIONS
NOTE:
Installing a jumper at
J6,
located at the upper-right corner of the main PCB
Assembly, will disable the
ON/OFF switch.
This is not recommended in battery powered applications.
KEY
FUNCTION
ON/OFF
Turns the Instrument on or off.
UNITS
Switches between pre-programmed selectable weight units.
ZERO
Sets the display to zero, programmable: 2% or 100% of capacity.
B/G – NET
Toggles between Gross and Net weights
• This apples only if a Tare Value has been entered greater than ZERO.
TARE
Automatically tares off displayed weight when key is pressed.
Simple RS232 output when key is pressed.
0-9
Used for Programming and inputting manual tares.
MENU
Gains access to the sub-menus in the Configuration Mode.
ARROW KEYS
Used for scrolling through the menu selections.
Depending on programmed selection, Tare Weight amount will do one of the
following.
• Be retained for reuse until changed, or if power is removed.
OR…
• Automatically clear when
Gross Weight returns to
ZERO
.