Section 2: Assembly

02/13

16

51315 Rev. 1

2.4. LOADCELL CONNECTIONS

1. Remove the screws on the back cover of the Indicator to access the main printed

circuit board inside the enclosure.

– Use caution to avoid pulling cables out of their connectors.

2. Bring the dressed end of the load cell cable through the strain relief connector on

the back of the instrument, allowing enough cable on the inside to reach the load
cell connection terminal on the main board.

3. Tighten strain relief as needed to grip the load cell cable.

4. Replace and refasten the back onto the Indicator.

2.5. INSTRUMENT WIRING

INSTRUMENT COLOR CODE

LOAD CELL

TB2 - 1

Black

(–) EXC

TB2 - 3

Green

(+) EXC

TB2 - 7

White

(+) SIG

TB2 - 8

Red

(–) SIG

GR

BL

WH

RD