General Technologies TA500 SmarTach+COP : Multisystem Engine Analyser User Manual
Page 2

Page 2
Table of contents.
1. Safety Rules
Page 1
2. Technical Specifications
Page 2
2.1 General specifications
Page 2
2.2 Electrical specifications
Page 2
3. Operation
Page 3
3.1 Instrument description
Page 3
3.2 LCD Display
Page 3
3.3 Buttons description and operation
Page 5
3.4 Measurement procedures
Page 7
3.5 Additional functions
Page 10
4. Application information
Page 12
4.1 Taking measurements
Page 12
4.2 Diagnostic using spark KV and burn time
Page 12
4.3 Common causes of long burn time or low spark KV
Page 12
4.4 Common causes of short burn time or high spark KV
Page 13
5. Maintenance
Page 14
5.1 Battery replacement
Page 14
5.2 Cleaning
Page 14
6. Warranty
Page 14
1. SAFETY RULES
• This instrument is designed for indoor use at temperatures between 32° and 104° F (0°C
and 40°C) and altitudes up to 6500 ft (2,000 meters).
• To ensure that the instrument is used safely, follow all safety and operating instructions
in this operation manual. If the instrument is not used as described in this operation
manual, the safety features of this instrument may be impaired.
• Do not use the instrument if the instrument, the capacitive pick-up or the flexible probe
looks damaged, or if you suspect that the instrument is not operating properly.
• When using the instrument, keep away from moving parts (fan, drive belts, etc) and hot
objects (exhaust pipes, muffler , catalytic converter, etc), to avoid personal injuries and
damage to the instrument, the capacitive pick-up or the flexible probe.
• Do not connect or apply more than 42 VDC or any AC current directly to the capacitive
pick-up or the flexible probe.
• At all times, to avoid electrical shock, use CAUTION when working with electrical circuits
above 60V DC or 25V AC rms. Such voltages pose a shock hazard.
• Do not operate this instrument with the battery cover off.
• To avoid electrical shock or damage to the instrument, do not exceed the specified input
limits.
Exceeding the limits listed above when using this apparatus, or not observing the
precautions listed above can expose you to physical injury and permanently damage
your instrument and/or parts and components of the vehicle under test.
2. TECHNICAL SPECIFICATIONS
2.1 General Specifications
Display:
LCD 4½ digits main display, 2 x 3½ digits for secondary displays,
indicators for low battery, number of cycles, ignition system,
functions and measurement units.
Update rate:
3 per second (for LCD).
Ignition system comp.: Coil on plug, coil near plug, DIS, conventional and magneto.
Engine cycles:
2 and 4 cycles and DIS.
Power:
9 Volt battery, type MN1604.
Auto power off:
Automatically powers off after 3 min. of no operation.
Battery life:
Approximately 20 hours (w/alkaline battery).
Probe length:
13.5” (34 cm) Including capacitive pick-up.
Dimensions:
6” x 4” x 1.5” (158 x 100 x 37 mm) without antenna.
Weight:
Approximately 14 Oz. or 406 g. (Including battery).
Included accessories: Padded hard carrying case, user’s manual, rubber holster and 1
x 9 Volt alkaline battery.
2.2 Electrical Specifications
•
The specifications below are typical at 23° C, and will vary slightly from device to device,
and with temperature. The input voltage should not exceed the indicated maximum
values, to prevent personal injury or damage to the instrument.
Function
Measurement
Range
Accuracy/Repetitivity
Input
Characteristics
RPM
200 to 19999 RPM
2 and 4 cycles and DIS
Accuracy: 0.5% ± 1 LSD
Input Impedance:
100KΩ + 1.5 nF
(Minimum).
Input Protection:
± 42 VDC Max.
Spark KV
0 to 50 Kv
Repeatability: 3% ± 1 LSD
Spark burn
time
0 to 10 ms
Accuracy: ± 0.1 ms