beautypg.com

FEC AFC1200 User Manual

Page 7

background image

)(& ,QF

Maximum allowable Final step time

FINAL STEP (TIME)

Maximum allowable fastening cycle time

1ST STEP (TIME)

Engineered fastening specification for rotation angle

FINAL ANGLE

30 ~ 50% of resultant torque for Hard joints
50 ~ 90% of resultant torque for Soft joints

SPEED CHANGE (TORQUE)

Engineered fastening specification at which angle control
begins

THRESHOLD 2 (TORQUE)

30 ~ 50% of FINAL ANGLE or resultant torque for Hard joints
50 ~ 90% of FINAL ANGLE or resultant torque for Soft joints

1st TORQUE/ANGLE

RECOMMENDATION

FUNCTION

{ Three-Step Fastening

P After presetting the fastening sequence (SET SEQUENCE Section 7.5) to perform

a two-step fastening, the System fastening parameters (PARAMETER SET
Section 7.1) must be configured according to the Engineered fastening
specification.

P Two-step fastening will be used primarily for joints that have a requirement to

synchronize with another spindle during the final stage of the rundown.
Examples: Connecting rod, main bearing cap, any multiple-spindle unit.

P The System will fasten to the 1st TORQUE/ANGLE during the specified 1ST STEP

time. Once either SPEED CHANGE TORQUE or 1st TORQUE/ANGLE is
reached, the System will switch to the specified TORQUE SPEED (Section 6.3).
When all fasteners have reached 1st TORQUE/ANGLE, the spindles will
synchronize and rotate simultaneously the specified number of degrees from
THRESHOLD 2 TORQUE to FINAL ANGLE within the specified FINAL STEP time.

TORQUE

FINAL

ANGLE

1ST STEP

FINAL

STEP

ANGLE

THRESHOLD 2 TORQUE

1st TORQUE / ANGLE

SPEED CHANGE

FIG. 6-1-2b Angle Control Functions for Two-Step Fastening

Chapter 6: Fastening Instructions

User Console Version A3.53

Page 6-7