beautypg.com

FEC AFC1200 User Manual

Page 2

background image

)(& ,QF

6.1

Fastening Control Methods

The AFC1200 System is user programmable to select from three different fastening methods,
referred to as Torque Control, Angle Control, and Yield Control methods. Each method can
be configured to perform the fastening in 1 to 4 incremental steps.

6.1.1 Torque Control Method

In Torque Control method, fastening is performed based upon attaining a desired torque
value. Fastening can be performed in 1 to 4 incremental step which will successively secure
the fastener to the specified torque values.

{ One-Step Fastening

P After presetting the Fastening sequence (SET SEQUENCE Section 7.5) to perform

a single step fastening, the System fastening parameters (PARAMETER SET
Section 7.1) must be configured in accordance with the Engineered fastening
specification.

P One-step fastening will be used primarily for joints which have no requirement to

synchronize with another spindle during the final stage of the rundown.
Examples: Pipe plugs, single spindle applications.

P The System will fasten to the STD torque value during the specified 1ST STEP

time. Once SPEED CHANGE TORQUE is reached, the System will switch to the
specified TORQUE SPEED (Section 6.3).

STD.

TORQUE

1ST STEP

ANGLE

SPEED CHANGE

FIG. 6-1-1a Torque Control Functions for One-Step Fastening

Maximum allowable fastening cycle time

1ST STEP (TIME)

30 ~ 50% of STD for Hard joints
50 ~ 90% of STD for Soft joints

SPEED CHANGE (TORQUE)

Engineered fastening specification

STD

RECOMMENDATION

FUNCTION

Chapter 6: Fastening Instructions

User Console Version A3.53

Page 6-2