beautypg.com

FEC AFC1200 User Manual

Page 14

background image

)(& ,QF

6.2

Monitoring Functions

The AFC1200 System is user programmable to select and set the monitoring limits for torque,
angle, time and three independent torque rate stages. Torque rate monitoring may be
configured to perform two different methods of calculations dependent upon the
characteristics of the joint.

6.2.1 Torque Monitoring

Torque Monitoring is a continuous process whenever the System is operating. In Torque
Control method, the High and Low Torque limits are set based upon the engineering
specification for that specific fastener. For Angle and Yield Control operations, the High and
Low Torque limits are either set by the engineering specification for that specific fastener, or
by determining the acceptable limits from a study of known good and bad assemblies. The
High Torque limit will stop the fastening process for Angle and Yield Control operations if it is
reached before attaining the desired angle or elongation, respectively.

6.2.2 Angle Monitoring

Angle Monitoring commences upon reaching the preset THRESHOLD 2 TORQUE value, and
continues until completion of the fastening process or until the High angle limit is reach,
whichever occurs first. In Angle Control method, the High and Low Angle limits are set based
upon the engineering specification for that specific fastener. For Torque and Yield Control
operations, the High and Low Angle limits are either set by the engineering specification for
that specific fastener, or by determining the acceptable limits from a study of known good and
bad assemblies. The High Angle limit will stop the fastening process for Torque and Yield
Control operations if it is reached before attaining the desired torque or elongation,
respectively.

TORQUE

HIGH ANGLE

LOWANGLE

ANGLE

1st TORQUE / ANGLE

ACCEPT AREA

FINAL TORQUE

HIGH TORQUE

THRESHOLD 2 TORQUE

LOWTORQUE

FIG. 6-2-2 Torque and Angle Monitoring Functions

Chapter 6: Fastening Instructions

User Console Version A3.53

Page 6-14