beautypg.com

Teledyne 8800A/8800B - Panel / Wall mount trace moisture analyzer User Manual

Page 42

background image

Glossary

35

impedance . . . . . . . . . . . . . . . the ratio of voltage to current at a specified frequency measured in

Ohms, a resistor of the same value would act the same as the mea-
sured circuit

in-situ . . . . . . . . . . . . . . . . . . measurement with sensor located in the process stream
intrinsically safe . . . . . . . . . . incapable of releasing enough electrical or thermal energy to cause

the ignition of flammable substances listed for a hazardous area
classification

LBS H

2

O/mmscf. . . . . . . . . . see - pounds of water per million standard cubic feet

LCD . . . . . . . . . . . . . . . . . . . Liquid Crystal Display - a display that uses a special material [that

is sensitive to electrical voltages] to affect the transmission or
reflection of light

monograph . . . . . . . . . . . . . . a systematic learned exposition of a subject, e.g. a chart represent-

ing dewpoint conversions for differing pressures.

National Electrical Code . . . . a set of US standards related to accepted practices for electrical wir-

ing

NFPA. . . . . . . . . . . . . . . . . . . National Fire Protection Agency (issuer of the National Electrical

Code (NEC))

NIST . . . . . . . . . . . . . . . . . . . National Institute of Standards and Technology
NPT . . . . . . . . . . . . . . . . . . . . National (American Standard) Pipe Taper; an ASTM (American

Society for Testing and Materials) standard of tube fittings with
tapered threads

parity . . . . . . . . . . . . . . . . . . . a way of incorporating error checking into a RS232 data transmis-

sion [on a character by character basis] to check if the data has been
received correctly

pounds of water per
million standard cubic feet . (LBS H

2

O/mmscf) the mass of water vapor present in unit volume

of moist air at standard temperature and pressure.
a measurement unit for moisture, typically used in the natural gas
industry

ppm . . . . . . . . . . . . . . . . . . . . parts per million - usually based on volume measure, but must be

stated whether it is by volume or by mass (weight)

ppmV . . . . . . . . . . . . . . . . . . parts per million based on volume measure, volume of water vapor

per total volume of gas for an ideal gas.

pressure correction . . . . . . . . computation of dewpoint at a pressure different from the pressure at

the sensor

PROM . . . . . . . . . . . . . . . . . . Programmable Read Only Memory - a device that can be pro-

grammed so that data is permanently stored in it [typically used for
computer programs]

RAM . . . . . . . . . . . . . . . . . . . Random Access Memory - a device that holds data as long as it has

power applied to it [the data can be changed with out limit]

regenerative dryer purge . . . . small flow of dry air from drying column passing through regener-

ating column and desorbing water from desiccant at low pressure

response time . . . . . . . . . . . . time it takes for a sensor to react to change in its environment
RG58. . . . . . . . . . . . . . . . . . . a type of coaxial cable - the letters/numbers refer to the electrical

characteristic of the cable [resistance/capacitance per foot of
length]