SPP Pumps Transformer Oil Pumps User Manual
Page 11
Operators Instructions for
Transformer Oil Pumps
Manual No/Rev
W61-001E / 9
Our policy is one of continuous improvement and we reserve the right to alter specifications without giving notice.
Page 9
1
4.6.1 Three-phase Supply Units
Check phasing of supply is to the
standard phase sequence of Red-
Yellow-Blue. Connect wiring as
shown in the diagram.
It is essential to check that the
wiring gives the correct direction
of pump rotation. For this
purpose only, the pump may be
run very briefly without oil
lubrication/cooling.
To check rotation before suction pipework is connected:
Visually check through the suction branch that the rotation is as shown on
the casing.
To check rotation with pump installed
A "Phase & Continuity Indicator", connected to the correct pump terminals,
will give confirmation of the direction of rotation.
The visual indicator, fitted to some pumps, will also show the direction of
rotation when filled with oil.
Note: Do not rely on the direction of oil flow. Some types of pump will give
the same direction of flow whatever the rotation.
4.6.2 Single Phase
TERMINAL
MAINS SUPPLY
CABLE
Connect electrical power supply
Z1/U1
Brown
cables as shown in the table
V1/U2
Black
See also the label inside the
W1/Z2
One capacitor lead
terminal box cover.
V1/U2
Other capacitor lead
W1
U1
Z1
Z2
U2
V1
TERMINAL
U1/Z1
BROWN
TERMINAL
W1/Z2
GREY
TERMINAL
V1/U2
BLACK
ATTENTION