Installation – Fulton Hopkins (HPN) Horizontal Coil Thermal Fluid (hot oil) Heater User Manual
Page 10
![background image](/manuals/345501/10/background.png)
© The Fulton Companies 2014
INSTALLATION
HPN-IOM-2014-0416
SECTION 2
2-4
Specifi cations
MODEL 100S
200S
350S
600S
800S
1000S
1200S
1400S
1600S
2000S
2400S
3000S
4000S
Heat Output
Million BTU/hr
1
2
3.5
6
8
10
12
14
16
20
24
30
40
Flow Rate-Standard *1
GPM
75
150
265
425
600
725
900
1050
1200
1500
1800
2250
3000
Flow Rate-Low Flow *2
GPM
40
75
135
225
300
375
450
525
600
750
900
1125
1500
Circulating Pump Motor - STD
HP
7.5
15
20
30
40
50
60
75
100
100
125
150
200
Circulating Pump Motor - LF
HP
7.5
7.5
15
20
30
30
40
30
40
50
60
75
100
Blower Motor
HP
1/3
1
2
7.5
10
10
5
7.5
7.5
15
20
25
30
Light Oil (approx. fuel usage)*3
GPH
8.8
17.5
30.6
52.5
70
87.5
104.9
122.4
139.9
174.9
209.8
262.3
349.7
Natural Gas (approx. fuel usage)*3
FT3/hr
1,334
2,667
4,667
8,000
10,667
13,334
16,000
18,667
21,334
26,667
32,000
40,000
53,334
Pressure Drop - STD PSI
10
23
11
16
16
13
16
10
15
14
15
9
21
Pressure Drop - LF PSI
15
19
11
14
15
18
14
11
15
20
14
12
17
Dimensions
MODEL 100S
200S
350S
600S
800S
1000S
1200S
1400S
1600S
2000S
2400S
3000S
4000S
(A) Overall Height (w/o Stack)
IN
51
60
62
82
82
105
105
106
106
125
133
133
142
(B) Overall Width
IN
42
50
50
74
93
87
103
110
110
123
130
130
142
(C) Overall Length
IN
115
152
211
231
302
311
360
408
444
450
550
575
648
Inlet/Outlet Connections
IN
2
3
3
4
6
6
8
8
8
10
12
12
12
Thermal Liquid Volume
GAL
45
86
168
426
661
724
853
1168
1400
1721
2322
3180
4626
Approx. Dry Weight
LBS
3,936
6,800
9,052
14,350
18,500
23,100
26,800
30,500
32,600
41,400
68,000
74,000
80,000
Approx. Flooded Weight
LBS
4,310
7,514
10,447
17,886
23,987
29,110
33,880
40,195
44,220
55,685
87,273
100,394
118,396
Floor Loading
LB/FT3
129
143
143
151
123
155
132
129
131
145
176
194
186
TABLE 1 - SPECIFICATIONS AND DIMENSIONS
Note: All dimensions are approximate. Please consult factory for your job specifi c drawings with dimensions.