Bosch HMT75M651 - Inox Micro-ondes User Manual
Page 2
Installation Instructions
Models: CET304, CET365, CEP304, CEP365, CEP456
TABLE OF CONTENTS *
*NOTE: The blocked letters, such as A, shown below, refer to illustrations on
Pages 2 & 4. Match these to the related text pages.
Overall Dimensions A ................................................................................................ 2
Power Supply B ............................................................................................................ 2
Cabinet Preparation and Clearances C .............................................................. 2, 3
Junction Box Location D ............................................................................................ 2
Countertop Cutout Dimensions E ......................................................................... 2
Installing the Cooktop F ............................................................................................ 4
Secure Cooktop to Countertop G ......................................................................... 4
Solid Surface Countertop Installs H ........................................................................ 4
Installation above a Single Oven I, J, K, and L ................................................. 4
Electrical Connection .................................................................................................. 5
OVERALL DIMENSIONS
A
See Illustration A, Page 2. These dimensions are overall.
POWER SUPPLY
B
ELECTRICAL POWER CONNECTION
FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 4
wire, 60 Hz, with the following circuit breaker
requirements: Models CET304 or CEP304 at 30 Amps;
Models CET365 or CEP365 at 40 Amps or Model
CEP456 at 50 Amps
Install a junction box (not supplied), below the counter
top within 3 feet of flexible conduit (supplied) located
at the right rear corner of the cooktop rough-in box.
IMPORTANT:
Save these instructions for Local Electrical Inspector’s use.
INSTALLER:
Please leave these Installation Instructions with this unit for the owner.
OWNER:
Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
JUNCTION BOX LOCATION
D
Plan the installation of the unit so that the location of
the junction box is within 3 feet of the right rear of
the cooktop bottom. It must be accessible from
the front of the cabinet. (An exception to this
location would be for a cooktop installation over a
single electric oven In that situation, refer to Pages 4
and 5 and Figures I, J, K and L.
PAGE 1