On model with separate spray, place the SPRAY HOLDER (1)

into the appropriate mounting hole. Assemble the SPRAY

HOLDER WING NUT (2) onto the shank of SPRAY HOLDER (1)

from below and hand tighten. Do not use putty.
For installation less spray, cap off SPRAY HOSE

CONNECTION (3) with PIPE CAP (4).

3

INSTALL SPRAY HOLDER

1

1

2

5

4

2

TEST INSTALLED FAUCET

Move HANDLE down into "off" position and remove

AERATOR (1).
Turn on water supplies and check connections for leaks

.

Operate HANDLE (2) up and down, left and right to flush

water lines thoroughly.
For faucet with spray, direct SPRAY HEAD (3) into sink and

activate SPRAY (3). Check hose connections for leaks.
Move HANDLE (2) down to "off" position and replace

AERATOR (1).

CHECK CONNECTIONS

FOR LEAKS

6

3

4

CONNECT HOSE SPRAY

Feed SPRAY HOSE (5) through SPRAY

HOLDER (1) and attach COUPLING NUT (6)

of HOSE (5) to SPRAY HOSE CONNECTION (3)

on valve body. Tighten COUPLING NUT (6)

firmly.

2

SPRAY HOSE

CONNECTION

MAKE WATER SUPPLY CONNECTIONS

Turn off hot and cold water supplies before beginning.

Connect FLEXIBLE SUPPLIES (1, 2) directly

to wall supplies. Connection on fitting

supplies are 3/8" compression. Connect

left supply to Hot (Marked with a Red Line)

and right supply to Cold wall supply. Use

adjustable wrench to tighten connections.

Do not over tighten.

Faucet supplies are 21" long from faucet base.

Note: If additional supply length is

required, installer must purchase

additional parts separately.

Important: If SUPPLY HOSES (1, 2) are

too long, loop as illustrated to avoid kinking.

M 9 6 5 115 _ Rev. 1. 3

1

2

COLD

HOT

3