beautypg.com

PSA LIF5800RL User Manual

Page 15

background image

13

8.

BATTERY INSTALLATION , REPLACEMENT AND TEST

8.1 Battery Installation for LIF5800

8.1.1 The smoke alarm uses one 9V battery to automatically provide back-up

power to the alarm if AC power fails. The battery will operate the alarm for
approximately one to three months with AC power off.

8.1.2 The smoke alarm has a low battery indicator that will cause the unit to chirp

and flash the Red LED at approximately 32 second intervals for a minimum of 7
days. Missing battery with main power connected will cause the unit to chirp
and flash the Red LED at approximately 32 second intervals.

8.1.3 Replace battery when chirping occurs. To ensure proper operation, the bat-

tery should be replaced once a year.

8.1.4 To replace battery, remove alarm from mounting base(see section 6.2) and

remove the battery from compartment. Replace the old battery with a new one.

8.1.5 USE ONLY THE FOLLOWING 9-VOLT

ALKALINE BATTERIES FOR

REPLACEMENT:

EVEREADY/ENERGIZER 522

DURACELL MN1604, MX1604

These batteries can be purchased

at your local retail outlet or super-

market.

Caution: Use only specified bat-

teries. Use of different battery

may have a detrimental

effect on operation or may

cause the battery to explode re-

sulting in injury or fire.

RED BATTERY LEVER

Australia Patent

S/N 2008200075

Australia Patent

S/N 2008200075

1398-7208-03:_ 2012.6.13 4:24 PM Page 13

This manual is related to the following products: