Alliance Laundry Systems UF250PV Tilt User Manual
Page 35
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation
33
F232102
The power cable should be disconnected by one of two
methods. Either a plug socket combination that is
interlocked with a combined switch or a fixed
disconnect that provides relief from mechanical strain
on connection points should be used. Both methods
must comply with the authority having jurisdiction at
the point of installation and/or the National Electric
Code, article 400-5, EN60204 section 15.4.3. The
service disconnect mechanism should be between
2 and 6 feet (0.6 to 1.9 m) above the floor and should
be easily accessible.
Cabinet Freestanding
Electrical Specifications
Voltage Designation
Standard
Electric Heat
M
ode
l
Code
Vo
lt
a
g
e
Cyc
le
P
h
ase
Wi
re
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
A.W
.G.
mm
2
Full Loa
d
Am
p
s
Cir
c
uit
Br
eake
r
A.W
.G.
mm
2
135
N
440 – 480
50-60
3
3
15
30
10
3x4
78
95
4
3x25
P
380 – 415
50-60
3
3
15
30
10
3x4
78
95
4
3x25
Q
200 – 240
50-60
3
3
29
60
6
3x16
N/A
250
N
440 – 480
50-60
3
3
28
40
8
3x10
N/A
P
380 – 415
50-60
3
3
32
40
8
3x10
N/A
Q
200 – 240
50-60
3
3
56
70
6
3x16
N/A
NOTE: Wire sizes shown are for copper, THHN, 90° conductor per NEC article 310.
Table 6