beautypg.com

American Dryer Corp. AD-75 User Manual

Page 50

background image

46

B. ADJUSTMENTS

7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER

Inspect bolts, nuts, screws, (bearing set screws), non-permanent gas connections (unions,

shut-off valves, orifices, and grounding connections). Motor and drive belts should be

examined. Cracked or seriously frayed belts should be replaced. Tighten loose V-belts when

necessary. Complete operational check of controls and valves. Complete operational check of

ALL safety devices (door switches, lint drawer switch, sail switch, burner and hi-limit

thermostats).