20
2. ELECTRICAL SERVICE SPECIFICATIONS
A. Gas and Steam Models
IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models
contact the factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that
is affixed to the back side of the upper/top control door. In the case of 208
VAC or 230/240 VAC, the supply voltage must match the electric service
specifications of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to
dryer components due to improper voltage connections will automatically
VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
ADG-75 (Gas)
ADS-75 (Steam)
E
LECTRICAL
S
ERVICE
S
PECIFICATIONS
(
PER DRYER
)
IMPORTANT: 208 VAC
AND
230/240 VAC ARE NOT THE SAME. W
HEN
ORDERING
,
SPECIFY
EXACT
VOLTAGE
.
NOTE:
A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MIMIMUM
WIRE SIZE*
FUSING
CIRCUIT
BREAKER
D
UAL
E
LEMENT
T
IME
D
ELAY
60 Hz
50 Hz
120
1ш
2
13
---
10
20
20
208
1ш
2
8
---
14
12
15
208
3ш
3/4
5
---
14
8
15
240
3ш
3/4
5
5
14
8
15
240
1ш
2
7
7
14
12
15
380-400
3ш
3/4
---
3
14
5
15
416
3ш
3/4
---
3
14
5
15
460
3ш
3/4
3
---
14
5
15
* AWG Stranded Wire ... for individual lenghts less than 100 feet.