45

WARNING

: When cleaning steam coil fins, be careful not to bend the fins. If fins are bent,

straighten by using a fin comb which is available from local air-conditioning supply house.

90 DAYS

1. Remove lint from around basket (tumbler), drive motors, and surrounding areas.

2. Remove lint from gas valve burner area with a dusting brush or vacuum cleaner attachment.

3. Clean any lint accumulation in and around both the blower and drive motor casing openings.

NOTE

: To prevent damage, avoid cleaning and/or touching ignitor/flame-probe assembly.

EVERY 6 MONTHS

Inspect and remove lint accumulation in customer furnished exhaust duct work system and from

dryers internal exhaust ducting.

NOTE

: THE ACCUMULATION OF LINT IN THE EXHAUST DUCT WORK CAN

CREATE A POTENTIAL FIRE HAZARD.

NOTE

: DO NOT OBSTRUCT THE FLOW OF COMBUSTION and VENTILATION AIR.

CHECK CUSTOMER FURNISHED BACK DRAFT DAMPERS IN THE EXHAUST
DUCT WORK. INSPECT and REMOVE ANY LINT ACCUMULATION WHICH
CAN CAUSE THE DAMPER TO BIND or STICK.

NOTE

: A back draft damper that is sticking partially closed can result in slow drying and

shutdown of heat circuit safety switches or thermostats.

NOTE

: When cleaning the dryer cabinet(s), avoid using harsh abrasives. A product intended

for the cleaning of appliances is recommended.

STEAM MODELS-

clean the steam coil fins. We suggest using compressed air and a vacuum cleaner

with brush attachment.