B. Electric Models Only

IMPORTANT: Figures shown are for non-reversing models ONLY. For reversing models

contact the factory.

IMPORTANT: The dryer must be connected to the electric supply shown on the data label that

is affixed to the back side of the upper/top control door. In the case of 208 VAC

or 230/240 VAC, the supply voltage must match the electric service

specifications of the data label exactly.

IMPORTANT: The wire size must be properly sized to handle the related current.

WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to dryer

components due to improper voltage connections will automatically
VOID THE WARRANTY.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or

obligation.

APPROX. AMP

D

R

AW

IMPORTANT: 3 phase figures shown are for a 3 wire service ONLY.

ADE-75 (Electric)

E

LECTRICAL

S

ERVICE

S

PECIFICATIONS

(

PER DRYER

)

IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTE:

A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify

correct breaker size according to appliance amp draw rating and type of breaker used.

C

Circuit breakers for 3Ø dryers must be 3-pole type.

APPLIED VOLTAGE/PHASE/FREQUENCY

KW

208 / 1ø/ 60Hz

240 / 1ø/ 60Hz

208 / 3ø/ 60Hz

240 / 3ø / 50/60Hz

380 / 3ø / 50Hz

416 / 3ø / 50Hz

460 /3ø / 60Hz

20

105

90

---

---

33

---

---

24

---

---

72

63

---

36

33

30

---

---

88

77

---

45

41

33

---

---

---

---

53

---

---

36

---

---

104

92

---

53

48

40

---

---

---

---

---

59

---